Skip to content
LoadShackleINSTRUMENTED RIGGINGEngineering desk
Menu

LoadShackle / Product configurations / Custom load pins

LSH-PIN / DRAWING-CONTROLLED

Custom load pins for the joint you already have.

Start with the existing shackle or clevis drawing, the actual support/contact arrangement and the measuring force. Review the instrumented pin as part of that connection before changing a load-bearing component.

Configuration review ·

Horizontal metal flanged sensing pin with two circular shear recesses, hexagonal cable gland and black cable
Source-matched 20 mm flanged sensing-pin referenceThis real product reference corresponds to the nominal data below. Its measuring range is not the WLL of a shackle or clevis assembly; supplied dimensions and configuration require an issued drawing.

EXISTING JOINT / CONTACT / RETENTION / SENSING AXIS

A custom pin starts with the load path, not just the diameter.

Body and support

Send the body or clevis drawing, bore fits, lug spacing, centre tongue/bobbin width and any wear, bushings or articulation constraints.

Identify the assembly
Original maker/part, drawing revision and responsibility for approving the changed joint.

Measuring force and direction

State the required force range in N, kN or lbf, expected direction, overload/dynamic conditions and measurement purpose.

Keep ratings separate
Sensing range, structural design loads and assembly WLL require separate definitions.

Retention and signal exit

Provide keeper/anti-rotation details, axial retention, available cable bend space, guard envelope and installation access.

Control orientation
The sensing axis and installed contact must match the agreed calibration arrangement.

Use D/L/A/B/C as drawing references.

LABDCentre tongue/ bobbinC: existing groove datumSupport / span datums must match your drawing
Concept only, not a production drawing. D/L/A/B/C identify requested drawing references; they are not equations or approved groove locations.
D — pin/bore reference
Identify diameter, fit, tolerance and any bushing arrangement on the existing drawing.
L — loaded/support span
Define the actual support datums. The concept shows support centres; your drawing controls their definition.
A — centre contact width
State the loaded tongue, eye or bobbin contact, including required clearances.
B — outer support reference
Identify lug/contact width and whether both sides share the same geometry.
C — existing shear-plane / groove datum, if known
Attach the corresponding detail from your existing drawing. If not defined, leave it for drawing review; do not infer groove positions.

Do not calculate sensing groove positions from these intake labels. Groove geometry, stress review, material, fatigue/dynamic conditions and machining release belong to the agreed engineering scope. The 52 mm projection from the flange inner face to the pin end is not a substitute for L.

Download the custom-joint worksheet and NDA discussion draft

SOURCE-REVIEWED REFERENCE / NOMINAL DATA

A 20 mm pin reference, with force and geometry kept separate.

This source-matched reference corresponds to the flanged pin pictured on this page. Its measuring ranges are not lifting WLLs. The quoted part, support arrangement, calibration and issued drawing must identify the actual supplied configuration.

Nominal geometry references — original drawing is in mm
ReferenceValue (mm)
Nominal shaft diameter20
Flange diameter29
Projection from flange inner face to pin end52
Flange inner face to groove reference46.6
Flange thickness6.6
Nominal measuring-range references — not a shackle rating
Range referenceFull scale (kN)
0–2 kN source range2
0–3 kN source range3
0–5 kN source range5
0–10 kN source range10
0–15 kN source range15

Source drawing calls out Ø20 h6. The original millimetre tolerance designation remains controlling; the inch column is a nominal conversion, not a new tolerance or manufacturing release. Both axial references start at the flange inner face: 52 mm to the pin end and 46.6 mm to the drawing’s groove reference. The 52 mm projection excludes the 6.6 mm flange. Neither is automatically your joint’s loaded span L.

Rated bridge output
1.0 ±10% mV/V
Recommended excitation
5–10 V
Material description
Stainless steel; exact grade to agree
Protection class
IP65 for this reference
Source-listed sensor safe / maximum overload
150% / 200% of full scale
Non-linearity
±0.5% F.S.
Hysteresis
±0.5% F.S.
Repeatability
±0.5% F.S.
Operating / compensated temperature
−20 to +80°C / −10 to +60°C

Sensor overload figures do not establish a structural proof load, breaking load or lifting design factor. These are separate source-listed characteristics, not a combined accuracy guarantee. IP65 is not a subsea pressure qualification. Bridge excitation is separate from the supply requirements of any optional amplifier or PLC interface. Reference reviewed 2026-11-25.

Request this reference or submit your existing drawing

A second physical pattern is not the same specification.

The upright pin shown here illustrates a different flange, retention and exit arrangement. Do not apply the 20 mm reference dimensions, measuring range or protection data to this separate pattern.

Choose a starting geometry only after reviewing the mating joint. A cable, bridge, amplified or digital interface changes the electrical scope; it does not approve a mechanical substitution.

Upright metal sensing pin with two circular shear recesses, stepped wide base and side circular electrical connector
Separate upright flanged-pin patternDifferent real source pattern. The 20 mm reference table does not describe this pin; its dimensions, measuring range and configuration require separate review.

Define the written deliverables before a prototype.

  • Scope and drawing

    Existing joint revision, proposed pin drawing, force/rating definitions, material, tolerances, retention and installation boundaries.

  • Measurement acceptance

    Contact/support fixtures, output/readout chain, calibration range, loading directions and separate error characteristics.

  • Structural and environmental scope

    Required review, proof/NDT/material documents, service conditions and any assembly-level approval responsibilities.

  • Commercial scope

    Quantity, development/fixture work, reference or new geometry, drawing release, prototype criteria and project-specific dates.

Availability, design effort, calibration scope, pricing and lead time follow the agreed configuration. A request does not release production. Use the four written releases.

DRAWING REVIEW / EMAIL RFQ

Build a specification your engineer can review.

Choose the connection, signal and documents. Review the complete English RFQ, then open your email app or copy it into your existing project thread.

Attach your drawing in your own email app. Company information and selections stay in this browser until you choose to send or copy them.

Selected option allowancesNot selected

Budget additions only. Items marked Project quote, the base assembly, interface matching and third-party attendance are quoted separately.

Download RFQ worksheets and the NDA draft

Request scope and units

Changing units converts entered numeric loads and dimensions. Depth and drawing notes keep their explicitly stated units. Converted numbers are nominal; the original drawing tolerances control.

Five-dimension drawing references

Use your existing joint drawing. Leave unknown values blank; groove positions and tolerances are agreed in the assembly drawing, not guessed from WLL.

Readout options and document scope

Calibration, structural proof, NDT and third-party acceptance are separate scopes. Selecting an item requests review; it does not establish certification or a safety-rated function.

Project context and confidentiality

Review the unsigned NDA draft. Confidentiality starts with agreed terms and authorized signatures, not a checkbox.

Open in email app

Your email app sends the message. Attach drawings there. Copy RFQ also keeps the complete text for your existing project thread.

BEFORE YOU ISSUE THE RFQ

Pin force range, joint geometry and replacement responsibility

Can I replace a standard shackle pin by matching its diameter?

Diameter alone is insufficient. Review the body/joint, support and contact arrangement, material, retention, load direction, calibration setup and approval responsibilities. A sensing-pin range does not establish the WLL of the modified assembly.

Is the 20mm reference rated for 15 tonnes?

No. Its source-listed measuring ranges are 2, 3, 5, 10 and 15 kN. These are force ranges, not metric-tonne lifting WLLs. The reference geometry and IP65 protection do not establish an assembly rating or a subsea depth capability.

Do the D/L/A/B/C fields create a finished manufacturing drawing?

No. They are intake references for your existing drawing. Define the actual support/contact datums, tolerances, orientation and retention. Values in a request, a conceptual illustration and converted nominal dimensions are not an approved manufacturing release.

Can the same pin be supplied with bridge, amplified or digital output?

Submit the required interface, supply, cable and receiver for review. The 20mm source reference is a mV/V bridge. Optional electronics, available space, environmental protection and calibration-chain scope must be confirmed for the actual offered design.

ASSEMBLY EVIDENCE / DOCUMENTS / WRITTEN RELEASES

Prepare the engineering review before placing the order.

Calculate a two-leg scenario and prepare a separate shackle load-direction review.