Rugged handheld
For a rigger standing clear of the load, request the display format, peak hold, units, tare and required channel count.
- Confirm the pairing
- Transmitter family, receiver model, accessories and calibration scope.
LSH-BOW / TELEMETRY REQUEST
Measure at the rigging connection and send readings to the receiver your team uses. Match the sensing assembly, telemetry architecture and operating profile before selecting the readout.
Configuration review ·

RECEIVER FIRST / PROTOCOL / DATA DESTINATION
For a rigger standing clear of the load, request the display format, peak hold, units, tare and required channel count.
For test records or multiple points, define the logging device, timestamps, export format and how each shackle is identified.
If a phone or tablet is required, identify the supported app, operating system, display behavior and deployment conditions.
Discuss proprietary 2.4GHz telemetry and BLE as specific architectures. The frequency name alone does not define the protocol, legal market access or useful working distance.
Country, deck/yard layout, obstructions, antenna positions and the distance between the shackle and receiver.
Requested live update interval, capture requirements, channel count, logging duration and loss-of-link indication.
Battery chemistry, replace/recharge method, working temperature, shift length and access for maintenance.
Ask for the selected model’s radio/range and endurance conditions, regional documentation and tested receiver pairing.
Put your operating target in the RFQ so the offered system can be reviewed against it. Ask for range and endurance evidence identifying the selected hardware and test conditions.
For a matched set, request individual serial/channel identification and define how multiple readings are combined or displayed. A multi-channel screen alone does not authorize a tandem lift or establish safe load sharing.
Check the calibration and assembly-record scopeState whether the readings support observation, test logging or a proposed control interface. Define loss-of-power/link behavior and the connected controller. A wireless display or alarm output is not, by itself, an approved overload protection function.
Review market and product-document responsibilitiesList shackles, compatible receiver, batteries/charging, logging hardware/software, guards, transit case and required documents separately. Availability, geometry, rating, cost and dates are confirmed for the quoted configuration.
Compare a permanently powered cabled connectionKEEPER / RADIO HOUSING / ANTENNA
This assembly reference shows a cylindrical sensing pin, retaining nut, lower keeper and flat antenna. Review the actual hook or sling clearance, impact protection, antenna position and battery access on the offered drawing.
The photograph identifies the visible arrangement. Protocol, receiver compatibility, capacity and environmental ratings remain specific to the quoted system.

DRAWING REVIEW / EMAIL RFQ
Choose the connection, signal and documents. Review the complete English RFQ, then open your email app or copy it into your existing project thread.
Attach your drawing in your own email app. Company information and selections stay in this browser until you choose to send or copy them.
Budget additions only. Items marked Project quote, the base assembly, interface matching and third-party attendance are quoted separately.
Your email app sends the message. Attach drawings there. Copy RFQ also keeps the complete text for your existing project thread.
BEFORE YOU ISSUE THE RFQ
No universal pairing is assumed. Identify the transmitter protocol, receiver model, channel capacity and destination interface. A radio frequency or connector label alone does not establish compatibility.
Those figures are not published here as LSH guarantees. The selected hardware, antennas, sight line, update rate, batteries, temperature and operating profile must support the quoted figures. Request the applicable test conditions and documentation.
No. Specify the required architecture and supported receiver or app. Frequency overlap does not make protocols interchangeable; a phone connection and a multi-channel industrial handheld serve different workflows.
This page concerns above-water telemetry. A submerged application needs a separately reviewed underwater signal path, pressure boundary and connector arrangement; use the subsea request page.
MEASUREMENT AT THE CONNECTION
Match bridge, analog or digital output to your receiving input.
Resolve sling bearing, crown geometry and heavy-lift test scope.
Define the pressure boundary, connector and underwater signal path.
Match existing joint datums and a calibrated sensing-pin range.
Compare original-body sourcing and the complete sensing assembly.
ASSEMBLY EVIDENCE / DOCUMENTS / WRITTEN RELEASES
Calculate a two-leg scenario and prepare a separate shackle load-direction review.
Separate calibration, structural proof and the records that identify the supplied assembly.
Define the market, product boundary, responsible parties and equipment document scope.
Agree scope, drawing, prototype and production releases before the project moves on.