Skip to content
LoadShackleINSTRUMENTED RIGGINGEngineering desk
Menu

LoadShackle / Rigging calculator

TWO-LEG STATICS / ASSEMBLY REVIEW

Sling tension calculator and shackle side-load review.

Calculate ideal per-leg tension and prepare an assembly review. This tool does not establish allowable shackle WLL.

Reviewed · English engineering reference

1 / IDEAL SYMMETRIC STATIC GEOMETRY

Enter force and define the angle.

Geometry inputs

Force units are explicit. Valid angle conventions convert to the same geometry. Invalid angles clear when their convention changes; force conversions outside numeric range clear the force input.

IDEAL PER-LEG TENSION / NOT WLL

5.774kN

T/W = 0.5774. Equal sharing is assumed.

Vertical component / leg
5 kN
Horizontal magnitude / leg
2.887 kN

θ 60° included · α 30° vertical · β 60° horizontal

No allowable shackle WLL, side-load permission or lift approval is calculated.

θ = 60°WEach leg T = 5.774 kN
Ideal geometry only; no hardware, dimensions or rated assembly are shown.

REPRODUCIBLE EXAMPLES

Compare a stated hypothetical scenario.

Reset changes geometry only. Assembly category, reported side angle, manual reference and project context stay together. Example drawings show geometry, not product hardware.

2 / SEPARATE ASSEMBLY LOAD-DIRECTION REVIEW

Report φ from the actual assembly datum.

Shackle direction and identity

Assembly rating remains unresolved

Side-load direction unresolved. Identify the assembly and its angle datum.

Model/manual reference missing. Identify the exact assembly, revision and permitted load direction.

Allowable side-load WLL: not established by this tool.

A named reference supplied by a requester is not verification of its approval scope. No chart factor is automatically assigned.

3 / COMPLETE SCENARIO HANDOVER

Send the geometry and the unresolved assembly questions together.

Optional project context

Selections stay in this browser until you choose to copy, download or use your email app. Attach the actual sketch and manuals there.

Open in email app

Your email app sends the message. Attach drawings there. Copy request also keeps the complete text for your existing project thread.

Get the blank geometry and assembly-review worksheet

WHAT THE NUMBERS HELP YOU DECIDE

Four distinctions to keep with the result.

Define the angle

A number such as 60° has different consequences when it means included, vertical or horizontal angle.

State the assumptions

Centred static load and equal sharing are inputs to the model, not findings about the real installation.

Keep ratings separate

Calculated force, calibrated measuring range and an assembly WLL answer different questions.

Resolve the direction

The reported shackle angle needs its own datum, model and written instructions. A sling angle does not supply them.

One geometry can have three angle values.

Symbols used by this page; check the definitions in any other document
Input conventionDefinitionEquivalent relationship
Included θBetween both legsθ = 2α
Vertical αOne leg from verticalα = θ/2
Horizontal βOne leg from horizontalβ = 90° − α

θ = 60° included

θ = 60°WEach leg T = 5.774 kN
Ideal geometry only; no hardware, dimensions or rated assembly are shown.

α = 30° from vertical

α = 30°WEach leg T = 5.774 kN
Ideal geometry only; no hardware, dimensions or rated assembly are shown.

β = 60° from horizontal

β = 60°WEach leg T = 5.774 kN
Ideal geometry only; no hardware, dimensions or rated assembly are shown.

The drawings above describe the same hypothetical 10kN case. Changing the tool’s convention converts the angle rather than merely relabelling the same number.

Resolve static equilibrium before interpreting tension.

With equal tensions T and a vertical share W/2 at each ideal leg, the vertical balance is 2T cos(α) = W. Equivalently, use the complementary horizontal angle β.

T = W / [2 cos(α)] = W / [2 sin(β)]

The displayed T/W factor multiplies the total force W. A chart using 1/sin(β) instead multiplies the vertical share W/2 for this two-leg model; those factors have different bases.

Each leg’s vertical component is W/2. Its horizontal component magnitude is (W/2) tan(α). Opposing horizontal components cancel at the ideal common apex; that fact does not establish an individual shackle’s permitted load direction or the forces at an actual joint.

The model assumes two legs, a centred suspended force, symmetric geometry and static equilibrium. Include all load carried by the modelled legs in W. The schematic does not establish real dimensions, clearances, contact or stiffness.

Identify the shackle’s location on the sketch. A component in one ideal leg carries T; the common collector has resultant W and its own bow/contact loading. A per-leg force is not automatically the reading or rating of a shackle elsewhere in the load path.

Read the force-unit conversion explicitly.

Conventional force definitions; not a local-gravity mass measurement
UnitDefinition usedEquivalent
kNKilonewton1,000N
Metric tonne-force, tf1,000kg × standard gravity9.80665kN
Pound-force, lbf0.45359237kg × standard gravity4.4482216152605N

Standard gravity is 9.80665m/s². See NIST’s pound-force definition and NIST SI conversion factors. Display rounding is numerical presentation, not sensor resolution, accuracy or an engineering tolerance. tf is metric, not a US short-ton unit.

See how the ideal force rises as the legs spread.

Calculated reference only: W = 10kN, equal static two-leg sharing
Included θHorizontal βT/WT per leg
0°90°0.55kN
30°75°0.51765.176kN
60°60°0.57745.774kN
90°45°0.70717.071kN
120°30°110kN
150°15° — outside usual reference1.93219.319kN

As horizontal β approaches 0°, the ideal tension becomes unbounded; β = 0° is not a valid calculation. Mathematical values beyond an equipment instruction’s limits do not authorize those configurations.

Three reproducible hypothetical scenarios.

Included-angle example

W 10kN; 60° included.

θ = 60°WEach leg T = 5.774 kN
Ideal geometry only; no hardware, dimensions or rated assembly are shown.

Ideal T = 5.774kN per leg. No component rating is selected.

Vertical-angle example

W 10kN; 45° vertical.

α = 45°WEach leg T = 7.071 kN
Ideal geometry only; no hardware, dimensions or rated assembly are shown.

Ideal T = 7.071kN per leg. No component rating is selected.

Metric force-unit example

W 10tf; 120° included.

θ = 120°WEach leg T = 98.066 kN
Ideal geometry only; no hardware, dimensions or rated assembly are shown.

Ideal T = 10tf per leg. No component rating is selected.

These examples are arithmetic, not completed lifts, measured tests or customer cases. Use the preset buttons in the tool to inspect their exact assumptions and export them for review.

A shackle side-load angle needs its own definition.

φManual-defined reference axisReported load vectorIllustrative vector only
This axis/vector sketch is not a shackle drawing. The actual manual defines the datum and permitted loading plane. φ is separate from θ, α and β.

The Crosby G-2100/G-2110 manual, printed page4 / PDF page5 includes the following general original-hardware chart within its ROV manual. Its stated scope is screw-pin and bolt-type Crosby shackles less than 3in; inline loading is perpendicular to the pin, with the specified angular loading in the bow plane.

Original Crosby source points only — not factors assigned by this calculator
Source angle from inlineListed source factorLSH allowance derived here
0–5°1.00Not established
45°0.70Not established
90°0.50Not established

This tool does not interpolate those points or transfer them to instrumented, round-pin, other-size or unreviewed assemblies. The original maker’s actual instructions control. A named body or document alone does not establish approval of a changed sensing-pin assembly.

Identify the original body and complete measuring connection

Know where a different analysis is needed.

Model boundaries and the next useful action
ConditionWhat this tool cannot establishNext step
Offset CG / unequal legsActual load sharingProvide geometry, CG and support/stiffness data for review.
Three/four legs or tandem cranesEqual division among attachmentsUse the actual load-sharing analysis and lift plan.
Shock, motion, snaggingPeak forces or a dynamic factorAgree service cases, controls and the appropriate assessment.
Unknown hardware/manualWLL, side-load permission, contact or fitIdentify exact assemblies and issued instructions.

OSHA wire-rope sling guidance conditions horizontal angles below 30° on manufacturer or qualified-person recommendation. The NSW rigging guide also highlights included-angle and unequal-sharing limits. Your controlling equipment instructions can be more restrictive than a mathematical domain.

Choose the next review task.

Different tasks require different evidence and cost scope
TaskUseful evidenceLimit / tradeoff
Geometry screenExplicit W, angles and assumptionsQuick comparison; no hardware rating or unequal-sharing analysis.
Assembly engineeringActual model, drawing, load direction and instructionsReview/fixture/document scope and schedule are project-specific.
Load monitoring planMatched sensors/readouts, channel identity and calibration chainObserve an agreed setup; measurement does not create capacity or approval.

Request assembly and calibration evidence, compare cabled or wireless measurement interfaces, and use the written engineering releases for a changed configuration.

Silver instrumented bow and waisted central bobbin next to an attached black four-key force indicator with eight status dots and a left cable connector
Measurement-chain referenceSource-based local-indicator assembly. A reading supports the agreed monitoring plan; it does not establish hardware capacity or lift approval.

Return to the complete scenario request · Download the blank review worksheet

BEFORE YOU ISSUE THE RFQ

Angles, units, source limits and scenario export

Which angle does the calculator use?

Choose the definition explicitly: θ is the included angle between the legs, α is each leg from vertical, and β is each leg from horizontal on this page. For this symmetric model θ = 2α and β = 90° − α. Other documents may use different symbols.

Is the calculated tension a shackle WLL?

No. T is an ideal model force. A complete assembly WLL is a separately established rating with its own instructions and conditions. The tool does not select a component, check its capacity or approve a lift.

Can I use the sling angle as the side-load angle?

No. The shackle angle φ needs its actual reference axis and loading plane from the assembly instructions. It is not automatically the included angle or either sling-leg angle.

Why does a horizontal angle below 30° show a warning?

Force rises sharply as the legs approach horizontal. OSHA wire-rope guidance conditions that range on manufacturer or qualified-person recommendation. Actual instructions can be more restrictive; an available mathematical result is not permission to use the arrangement.

Do the original Crosby factors apply to an LSH instrumented shackle?

No. The cited original-hardware chart has explicit screw-pin/bolt-type, size and loading-plane conditions. The tool shows its source points only as background and assigns no allowable WLL to an LSH assembly.

Does selecting round-pin hardware produce a derated rating?

No. Round-pin hardware is outside the cited screw-pin/bolt chart. The review requests the actual manufacturer instructions; it does not produce a round-pin side-load allowance.

Can the model divide a load equally among three or four legs?

No. This is a two-leg equal-sharing model. More legs, unequal lengths or an offset centre of gravity need a different analysis; dividing total load by the number of legs is not established here.

What do tf and lbf mean?

They are force units: metric tonne-force and pound-force at standard gravity. tf is not a US short ton, and neither entry silently means an unstated mass. The page explains the conversion constants.

Are shock, motion or tandem cranes included?

No. The model is static and symmetric. It does not calculate dynamic factors, crane load sharing, acceleration, snagging, shock or unequal support conditions. Select an unresolved arrangement and request review for those cases.

Will a live load reading make the arrangement acceptable?

A reading can support an agreed monitoring plan, but it does not increase WLL, approve side loading or resolve missing component/installation evidence. The actual measurement chain and rigging arrangement need their own review.

What is exported when an input is invalid?

The current raw inputs, validation issues, side-load identity questions and boundaries are retained. Previous numeric results are removed. A complete request remains available so the unresolved scenario can be reviewed.

Does this tool submit my scenario or require JavaScript?

Calculation changes need JavaScript. No-JavaScript visitors can read the default example, use its complete email link and download a blank worksheet. The site sends no enquiry POST; you choose whether to copy, download or send through your email app.

ASSEMBLY EVIDENCE / DOCUMENTS / WRITTEN RELEASES

Prepare the engineering review before placing the order.

Calculate a two-leg scenario and prepare a separate shackle load-direction review.